Bidirectional Adjustment; Restore Manufacturing Defaults - IBM 4247 A00 User Manual

Ibm printer user manual
Hide thumbs Also See for 4247 A00:
Table of Contents

Advertisement

5. Press
6. To exit from Power On Configuration, press Menu/Enter. Your new value is

Bidirectional Adjustment

This category lets you adjust dot registration and print quality by running the
bidirectional adjustment test pattern. The bidirectional alignment may need periodic
adjustment to maintain print quality.
The test pattern consists of these parts:
v Two groups of Hs (four lines each) with the current alignment value inserted
v A line of Hs and Is printed on one line.
You can set bidirectional adjustment from -6 to 6 (where each unit is 0.212 mm
[1/120 in.]). The default value is 0.
To change or check the Bidirectional adjustment:
1. Ensure the printer is powered off (O).
2. Press and hold Menu/Enter while powering on (|) the printer. The message
3. After start-up is complete, release Menu/Enter and the message PRINT OUT=NO
4. Press
5. Once you have acceptable print quality, press Menu/Enter to exit from the

Restore Manufacturing Defaults

Use this category to exit from the Power On Configuration Menu and restore the
factory default values. Your choices are:
v No (default)
v Yes
To Restore Manufacturing Defaults:
1. Ensure the printer is powered off (O).
2. Press and hold Menu/Enter while powering on (|) the printer. The message
3. After start-up is complete, release Menu/Enter and the message PRINT OUT=NO
4. Press
104
4247 Printer Model A00 User's Guide
until the message SENSOR TUNE=xxx displays, where xxx can be NO or
YES. If you want to select a value other than the one displayed, press
If you set SENSOR TUNE=YES, press . The sensors will be tuned and the
message SENSOR TUNE=NO will display indicating completion.
stored in NVM.
between them.
STARTING UP displays.
displays.
until the message BIDI ADJUST=xx displays, where xx can be -6 to 6. If
you want to select a value other than the one displayed, press
Once you change a value, press Online to print the adjustment test pattern.
After the test is completed the forms will advance above the tear bar so you can
view the printed pattern. If the quality is not acceptable, repeat step 4 again to
select another value.
Power On Configuration menu. Your new value is stored in NVM.
STARTING UP displays.
displays.
until the message RESTORE MFG=xxx displays, where xxx can be NO or
YES. If NO is selected, you exit from the Power On Configuration Menu and any
or .
or .

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4247-v03

Table of Contents