Width; Burst Width; Duty Cycle - Agilent Technologies InfiniiVision 3000 User Manual

Infiniivision 3000 x-series
Hide thumbs Also See for InfiniiVision 3000:
Table of Contents

Advertisement

14
Measurements

+ Width

+ Width is the time from the middle threshold of the rising edge to the
middle threshold of the next falling edge. The X cursors show the pulse
being measured. The Y cursor shows the middle threshold point.
– Width
– Width is the time from the middle threshold of the falling edge to the
middle threshold of the next rising edge. The X cursors show the pulse
being measured. The Y cursor shows the middle threshold point.

Burst Width

The Burst Width measurement is the time from the first edge to the last
edge on screen.

Duty Cycle

The duty cycle of a repetitive pulse train is the ratio of the positive pulse
width to the period, expressed as a percentage. The X cursors show the
time period being measured. The Y cursor shows the middle threshold
point.
Duty cycle = + Width
228
Burst width
Period × 100
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents