Agilent Technologies InfiniiVision 3000 User Manual page 270

Infiniivision 3000 x-series
Hide thumbs Also See for InfiniiVision 3000:
Table of Contents

Advertisement

17
Save/Recall (Setups, Screens, Data)
• Whether acquisitions are running. When stopped, data comes from the
• Whether the oscilloscope was stopped using [Stop] or [Single]. Running
• Whether only one channel of a pair is turned on. (Channels 1 and 2 are
• Whether reference waveforms are on. Displayed reference waveforms
• Whether digital channels are on. Displayed digital channels consume
• Whether segmented memory is on. Acquisition memory is divided by
• The horizontal time/div (sweep speed) setting. At faster settings, fewer
• When saving to a CSV format file, the maximum number of data points
When necessary, the Length control performs a "1 of n" decimation of the
data . For example: if the Length is set to 1000, and you are displaying a
record that is 5000 data points in length, four of each five data points will
be decimated, creating an output file 1000 data points in length.
When saving waveform data, the save times depend on the chosen format:
Data File Format
BIN, ALB
ASCII XY
CSV
See Also
270
raw acquisition record. When running, data comes from the smaller
measurement record.
acquisitions split memory to provide fast waveform update rates. Single
acquisitions use full memory.
one pair, channels 3 and 4 are the other.) Acquisition memory is
divided among the channels in a pair.
consume acquisition memory.
acquisition memory.
the number of segments.
data points appear on the display.
is 64K.
"Binary Data (.bin) Format"
"CSV and ASCII XY files"
"Minimum and Maximum Values in CSV Files"
Save Times
fastest
medium
slowest
on page 325
on page 332
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide