26
MIL-STD-1553/ARINC 429 Triggering and Serial Decode
• SYNC errors are displayed with the word "SYNC" within red angle
• Manchester encoding errors are displayed with the word "MANCH"

Interpreting MIL-STD-1553 Lister Data

In addition to the standard Time column, the MIL- STD- 1553 Lister
contains these columns:
• RTA — displays the Remote Terminal Address for Command/Status
• Word Type — "Cmd/Status" for Command/Status words, "Data" for Data
• Data — the 11 bits after the RTA for Command/Status words, or the 16
• Errors — "Sync", "Parity", or "Manchester" errors as appropriate. The
396
brackets.
within blue angle brackets (blue instead of red because a valid Sync
pulse started the word).
words, nothing for Data words.
words. For Command/Status words the background color is green to
match the decode text color.
bits of a Data word.
background color is red to indicate an error.
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide