8.2.1

Post-Power Connection Test Procedures Checklist

Table 35: Functional Checks on Component Indicators - TPM System Configuration
Functional Unit
Indicator
ES/6600 boards
SC boards
Media Gateway
boards
Fan Tray Module FM
Auxiliary Fan Tray
Module FMR
Indicator Status
SYSTEM
Yellow
Green
FAULT
Hot Swap
READY
Green
ALARM/USER
Flashing Green
Hot Swap
PWR
Green
ACT
Hot Swap
-
PWR
Green
Hot Swap
HRS
Push-button
Description
Basic board integrity checks were
completed
Awaiting BootP response
OFF
Normally OFF
LED is Red if the board fails
OFF
Normally OFF
LED is Blue during Hot Swap
The board's power module is
operational
Indicates correct operation of
processor
OFF
Normally OFF
LED is Blue during Hot Swap
The board is correctly powered
OFF
At initial power the Green ACT LED
is OFF for all boards. After software
is installed on the SC board, this
LED on the boards is lit, except for
the redundant, standby board, for
which it is OFF.
OFF
Normally OFF
LED is Blue during Hot Swap
All LEDs on
Refer to 'Alarm Indicators' on page
21
Normally ON
Power input received
OFF
Normally OFF
LED is Blue during Hot Swap
-
Not implemented in this version
8. Powering Up