Machine Parameter L:4
Initial
Switch
Setting
7
0
Printer registration
adjustment (Horizontal) at the
6
0
LCC in rotate printing.
5
0
4
0
Adjusts the start point to
3
0
print.
2
0
1
0
The plus setting increase the
0
0
left margin and the minus
setting decrease it.
Each setting changes by
0.1 mm.
Note: See Machine
Parameter K:4 for the normal
printing.
Machine Parameter L:5
Initial
Switch
Setting
7
0
Printer registration
adjustment (Horizontal) at the
6
0
1st cassette in rotate printing.
5
0
4
0
Adjusts the start point to
3
0
print.
2
0
1
0
The plus setting increase the
0
0
left margin and the minus
setting decrease it.
Each setting changes by
0.1 mm.
Note: See Machine
Parameter K:5 for the normal
printing.
Adjust
Switch
127 steps
32 steps
16 steps
8 steps
-8 steps
-16 steps
-128 steps
Note: Set this switch after setting the margin to
"0 mm" in Unique Switch F:2. Then, after setting
this switch, set the margin to the initial setting (4
mm) in Unique Switch F:2.
Adjust
Switch
127 steps
32 steps
16 steps
8 step
-8 steps
-16 steps
-128 steps
Note: Set this switch after setting the margin to
"0 mm" in Unique Switch F:2. Then, after setting
this switch, set the margin to the initial setting (4
mm) in Unique Switch F:2.
3-20
Usage/Comments
76543210
Settings
01111111
+12.7 mm
:
00100000
+3.2 mm
:
00010000
+1.6 mm
:
00001000
+0.8 mm
:
Å
00000000
0 mm
Initial setting
:
11110111
-0.8 mm
:
11101111
-1.6 mm
:
10000000
-12.8 mm
Usage/Comments
76543210
Settings
01111111
+12.7 mm
:
00100000
+3.2 mm
:
00010000
+1.6 mm
:
00001000
+0.8 mm
:
Å
00000000
0 mm
Initial setting
:
11110111
-0.8 mm
:
11101111
-1.6 mm
:
10000000
-12.8 mm