Muratec MFX-2500 Field Engineering Manual page 77

Hide thumbs Also See for MFX-2500:
Table of Contents

Advertisement

Machine Parameter B:2
Initial
Switch
Setting
7
0
Adjustment of the scanning
stretching and squeezing for
6
0
ADF.
5
0
(Vertical)
4
0
3
0
The plus setting stretch the
2
1
image data and the minus
1
0
setting squeeze it.
0
0
Each setting changes by
0.1%
Machine Parameter B:3
Initial
Switch
Setting
7
0
Adjusts the number of the
steps from DS2 ON to the
6
0
start of the scanning position.
5
0
(ADF)
4
0
3
0
1 step = 1 / 300 inches
2
0
1
0
0
0
Note: These values
are factory set and should
not be adjusted unless
instructed by a Muratec
technical representative.
Adjust
Adjust
63 steps 00111111
60 steps 00111100
2
50 steps 00110010
(0.084666 mm
2)
40 steps 00101000
30 steps 00011110
20 steps 00010100
10 steps 00001010
3steps
2steps
1 step
When Switch 7 is "1", it means " - ". For example,
"10000001" means "-0.17 mm".
3-6
Usage/Comments
Switch 76543210
Settings
00001111
+1.5 %
:
00001000
+0.8 %
:
00000100
+0.4 %
:
00000010
+0.2 %
00000010
+0.1 %
00000000
0 %
00000010
-0.1 %
00000010
-0.2 %
:
10000100
-0.4 %
:
10001000
-0.8 %
:
10001111
-1.5 %
Usage/Comments
Switch 76543210
Settings
+10.67 mm
:
+10.16 mm
:
+8.47 mm
:
+6.77 mm
:
+5.08 mm
:
+3.39 mm
:
+1.69 mm
:
00000011
+0.51 mm
00000010
+0.34 mm
00000001
+0.17 mm
00000000
31 mm
Å
Initial setting
Å
Standard
Å
Initial setting

Advertisement

Table of Contents
loading

Table of Contents