Second phone line
Unique Switch d:2 – Modem
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
1
Factory use only
3
0
Factory use only
2
1
ANSam output time
0: 3 sec
1: 4 sec
1
0
Factory use only
0
1
Factory use only
Unique Switch d:7 – Modem
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
The delay before post-
3
0
message is transmitted
2
0
Factory use only
1
0
Factory use only
0
0
Factory use only
Unique Switch i:4 – Miscellaneous
Initial
Switch
Setting
7
0
6
0
5
0
4
0
Time to change the display
3
0
between the first and second
phone lines. (sec)
2
1
1
0
0
1
Adjust
The time limit to output the ANSam (A sinwave
signal at 2100 Hz amplitude-modulated). Sets to "1"
when the V.8 handshake is hard to achieve.
Adjust
If retraining occurs due to the low reception signal
level and few delay of the telephone line, it may
overlap the second post-message. In this case,
increase the delay before the post-message is
transmitted.
Switch 4:
Switch 3:
Adjust
Set the time to change the display between the first
and second phone lines during the second phone
line is communicating.
When set to "0", show only the line during
communication.
Switch 76543210
6-95
Usage/Comments
Usage/Comments
0 ms 100 ms 200 ms 300 ms
0
0
1
0
1
0
Usage/Comments
Time
11111111
2550 sec
11111110
2540 sec
11111101
2530 sec
:
00000101
50 sec
:
00000011
30 sec
00000010
20 sec
00000001
10 sec
Options
1
1