Machine Parameter C:0
Initial
Switch
Setting
7
0
Mirror carriage standby
position adjustment
6
0
5
0
Adjusts the number of the
4
0
steps from the home sensor
3
0
of the mirror carriage OFF
2
0
to the standby position.
1
0
0
0
1 step = 0.140793616 mm
Note: These values
are factory set and should
not be adjusted unless
instructed by a Muratec
technical representative.
Machine Parameter C:1
Machine Parameter D:0
Initial
Switch
Setting
7
0
Scanning contrast level
adjustment in normal
6
0
resolution.
5
0
4
0
3
0
2
0
1
0
0
0
Adjust
Switch 76543210
63 steps 00111111
60 steps 00111100
50 steps 00110010
40 steps 00101000
30 steps 00011110
20 steps 00010100
10 steps 00001010
3 steps
2 steps
1 step
When Switch 7 is "1", it means " - ". For example,
"10000001" means "-0.17 mm".
C:9 --- Factory use only
Adjust
Switch 76543210
3-10
Usage/Comments
Settings
+8.87 mm
:
+8.45 mm
:
+7.04 mm
:
+5.63 mm
:
+4.22 mm
:
+2.82 mm
:
+1.41 mm
:
00000011
+0.42 mm
00000010
+0.28 mm
00000001
+0.14 mm
00000000
36 mm
Usage/Comments
01111111
Darkest setting
:
00001000
:
Å
00000000
Initial setting
:
10001000
:
11111111
Lightest setting
Å
Initial setting