2.4.9.7 I/C Cooling Fan Motor
The I/C Cooling Fan Motor prevents the temperature inside the machine (around the entire I/C) from
rising inordinately.
I/C Cooling Fan Motor (M9)
Electrical Component
M9
2.4.9.8 Ozone Fan Motor
Ozone produced by the PC Drum Charge Corona is absorbed by the Ozone Filter from the air being
drawn out of the machine by the Ozone Fan Motor.
Ozone Fan Motor (M8)
Ozone Filter
Electrical Component
M8
Control Signal
PJ18A-10
See block diagram of the printer.
Control Signal
PJ11A-1A
See block diagram of the printer.