Muratec MFX-2500 Field Engineering Manual page 80

Hide thumbs Also See for MFX-2500:
Table of Contents

Advertisement

Machine Parameter B:8
Initial
Switch
Setting
7
0
Leading edge document
margin adjustment
6
0
(FBS)
5
0
4
0
Adjusts the number of the
3
0
steps from the home sensor
2
0
of the mirror carriage ON
1
0
to the start of the scanning
0
0
position.
1 step = 0.140793616 mm
Note: These values
are factory set and should
not be adjusted unless
instructed by a Muratec
technical representative.
Machine Parameter B:9 --- Factory use only
Adjust
Switch 76543210
31 steps 00011111
16 steps 00010000
8 steps
4 steps
2 step
1 step
-1 step
-2 steps
-4 steps
-8 steps
-16 steps 10010000
-31 steps 10011111
3-9
Usage/Comments
Settings
+4.36 mm
:
+2.25 mm
:
00001000
+1.13 mm
:
00000100
+0.56 mm
:
00000010
+0.28 mm
:
00000001
+0.14 mm
Å
00000000
5 mm
10000001
-0.14 mm
:
10000010
-0.28 mm
:
10000100
-0.56 mm
:
10001000
-1.13 mm
:
-2.25 mm
:
-4.36 mm
Initial setting

Advertisement

Table of Contents
loading

Table of Contents