Unique Switch f:2 - Printer
Initial
Switch
Setting
7
0
Printing margin adjustment.
6
0
Each setting changes
5
1
by 0.1 mm.
4
0
3
1
2
0
1
0
0
0
Unique Switch f:3 — Printer
Initial
Switch
Setting
7
0
Printer contrast adjustment.
6
0
5
0
4
0
3
0
2
1
1
0
0
0
Unique Switch f:4
Adjust
Switch
Adjust
Switch
f:7 --- Factory use only
3-114
Usage/Comments
76543210
Settings
00000000
0
mm
00000001
0.1 mm
:
Å
00101000
4.0 mm
:
00110010
5.0 mm
:
00111100
6.0 mm
:
01000110
7.0 mm
:
01010000
8.0 mm
:
01011010
9.0 mm
:
01100100
10.0 mm
:
11001000
20.0 mm
:
11111111
25.5 mm
Usage/Comments
76543210
Settings
00000000
Not available
00000001
Lightest
00000010
:
00000011
:
Å
00000100
Normal
00000101
:
00000110
:
00000111
Darkest
00001000
Not available
:
Initial setting
Initial setting