Unique Switch c:2 - Reception
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
1
JBIG reception
0: No
1: Yes
2
0
Receive the junk fax
0: Yes
1: No
1
0
Print the communication
failure report with your unit in
Relay broadcast
0: No
1: Yes
0
0
Call request when remaining
memory size is small
0:No
1:Yes
Unique Switch c:3 - Reception
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
0
Factory use only
2
0
Factory use only
1
0
Number of seconds pseudo-
ring rings (seconds)
0
0
Switch 1:
Switch 0:
Unique Switch c:4
Adjust
Determines how documents from the remote fax are
received.
When the block junk fax feature was set to Mode 2
and the fax does not receive the TSI signal from the
remote fax, determines if receiving the fax other
than the remote fax number set to the block junk
dial list.
When set to "1", not only the sender unit but also
your unit prints the communication failure report in
Relay broadcast.
Setting this switch to "1" prompt call request to
transmitter when remaining memory size is small
after receiving the document which not the last
page.
Adjust
Sets the length of time the pseudo-ring rings.
30
40
50
60
0
0
1
1
0
1
0
1
c:9 --- Factory use only
3-106
Usage/Comments
Usage/Comments