Muratec MFX-2500 Field Engineering Manual page 191

Hide thumbs Also See for MFX-2500:
Table of Contents

Advertisement

Unique Switch h:5 - Operation
Initial
Switch
Setting
7
0
The time for the Auto power
off mode
6
0
5
0
(0 sec. to 7 sec.)
4
0
3
0
2
0
1
1
0
1
Unique Switch h:6
Unique Switch i:3 - Miscellaneous
Initial
Switch
Setting
7
0
Relay broadcast (Unique)
0: Not available
1: Available
6
0
Database polling Unique)
0: Not available
1: Available
5
0
SecureMail transmission
(Unique)
0: Not available
1: Available
4
0
Factory use only
3
0
Factory use only
2
0
Factory use only
1
0
Factory use only
0
0
Factory use only
Unique Switch i:4
Adjust
The machine will be in the Auto power off mode
after keeping to press the Energy saving key for the
time you set here.
Switch
Note: When set it to 0 sec., the machine will be in
i:2 --- Factory use only
Adjust
i:6 --- Factory use only
3-120
Usage/Comments
76543210
Settings
00000000
0 sec.
00000001
1 sec.
00000010
2 sec.
Å
00000011
3 sec.
00000100
4 sec.
00000101
5 sec.
00000110
6 sec.
00000111
7 sec.
the Auto power off mode immediately without
being in the Sleep mode after pressing the
Energy saving key.
Usage/Comments
Initial setting

Advertisement