Muratec MFX-2500 Field Engineering Manual page 377

Hide thumbs Also See for MFX-2500:
Table of Contents

Advertisement

Paper Feed Unit
Type
Vertical transport paper
leading edge detection
Size error detection
* The detection described
on the right is also made
during a 2-sided copy
cycle.
• Additional 1st cassette
Synchronizing Roller Sensor PC2 is not unblocked (H) within a given period
of time after Take-Up Sensor S3 of the Additional 1st drawer has been
blocked (L).
• Additional 2nd cassette
1. Take-Up Sensor S3 of the additional 1st drawer is not blocked (L) within
a given period of time after Take-Up Sensor S3 of the 2nd drawer has
been blocked (L).
2. PC2 is not unblocked (H) within a given period of time after S3 of the
additional 1st drawer has been blocked (L).
• Additional 3rd cassette
1. Take-Up Sensor S3 of the additional 2nd drawer is not blocked (L)
within a given period of time after Take-Up Sensor S3 of the 3rd drawer
has been blocked (L).
2. S3 of the additional 1st drawer is not blocked within a given period of
time after S3 of the additional 2nd drawer has been blocked (L).
3. PC2 is not unblocked within a given period of time after S3 of the
additional 1st drawer has been blocked (L).
• Additional 1st to 3rd cassette
The period of time is counted from when Take-Up Sensor S3 is blocked (L)
to when it is unblocked (H). The difference between the detected length and
the paper size which has been recognized is more than ±20 mm.
6-23