Muratec MFX-2500 Field Engineering Manual page 156

Hide thumbs Also See for MFX-2500:
Table of Contents

Advertisement

Memory Switch B:5 - Transmission
Initial
Switch
Setting
7
0
Program individual autodialer
attributes
0: No
1: Yes
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
0
Factory use only
2
0
Sending RTC signal when
transmission is canceled
0: Yes
1: No
1
1
Cancel redial if T.4.1 or T.4.4
error occurs
0: Yes
1: No
0
0
Action after EOR signal
0: Continue
1: Discontinue
Memory Switch B:6
Memory Switch C:0 - Reception
Initial
Switch
Setting
7
0
Data error rate
0: 10%
1: 20%
6
0
Pause one second after
sending CED
0: No (75 ms)
1: Yes (1 sec)
5
0
Factory use only
4
0
Factory use only
3
1
Receive speed (kbps)
Maximum receive speed may be slowed to compensate for poor phone lines.
2
1
2.4 4.8 7.2 9.6 12 14.4 16.8 19.2 21.6 24 26.4 28.8 31.2 33.6
1
0
0
0
1
0
0
0
Adjust
B:9 --- Factory use only
Adjust
0
0
0
0
0
0
0
0
0
1
1
1
0
1
1
0
0
1
1
0
1
0
1
0
3-85
Usage/Comments
Allows individual setting of memory switches B:0 as
attribute 1, B:1 as attribute 2, B:2 as attribute 3 and
B:3 as attribute 4 when one-touch and speed dial
locations are programmed. (Refer to page 3-97 for
settings.)
RTC signal is sent at the end of the transmission.
When set at "0", the machine will send the RTC if
the transmission is canceled. No error will occur.
When set at "1", an error will occur because RTC
will not be sent at the end of a canceled
transmission.
When set at "0", if a T.4.1 or T.4.4 error occurs, the
machine will not retry the transmission.
Sets action after receiving PPR four times at 2400
bps.
Usage/Comments
Determines the allowable number of erred lines out
of total lines received in a document.
A 2100 Hz CED signal disables echo suppression in
some telephone equipment. When set to "1", the
machine pauses one second after sending CED,
which allows echo suppression to restart. This may
help with problematic overseas reception.
0
1
1
1
1
1
0
0
0
0
1
0
0
1
1
1
0
1
0
1
1
1
1
1
0
0
0
1

Advertisement

Table of Contents
loading

Table of Contents