Paper Feed Unit
6.4.1.6.9 Paper Take-Up Retry Control
To minimize the occurrence of paper misfeed due to a slippery Paper Take-Up Roll, the Take-Up Solenoid
is energized a second time if a sheet of paper fails to reach the Take-Up Sensor within a given period of
time after it has been deenergized.
The control timing is as follows.
A misfeed results if the sheet of paper does not reach the Take-Up Sensor even after three paper take-up
sequences.