Muratec MFX-2500 Field Engineering Manual page 165

Hide thumbs Also See for MFX-2500:
Table of Contents

Advertisement

Memory Switch G:5 - Remote reception
Initial
Switch
Setting
7
0
Adjustment of CI detect time
6
0
5
0
4
0
3
0
2
0
Factory use only
1
0
Factory use only
0
0
Beep if fax handset hang up
0: Yes
1: No
Memory Switch G:6 - Remote reception and TAD interface
Initial
Switch
Setting
7
0
Off-hook / on-hook detect
time for remote reception
6
0
5
0
4
0
3
0
2
0
1
0
0
0
Memory Switch G:7
Adjust
Sets the time added to or reduced from the CI
detect time.
Switch 7 6 5 4 3
Determines if your machine beeps when having left
the fax's handset hanging up after communication.
Adjust
Sets the time interval between the off-hook/on-hook
condition for remote reception.
Switch 7 6 5 4 3 2 1 0
Note: Refer to Memory Switch G:1.
G:9 --- Factory use only
3-94
Usage/Comments
Time
1 1 1 1 1
15 msec
1 1 1 1 0
14 msec
:
:
1 0 1 0 0
4 msec
1 0 0 1 1
3 msec
1 0 0 1 0
2 msec
1 0 0 0 1
1 msec
0 0 0 0 0
0 msec
0 0 0 0 1
-1 msec
0 0 0 1 0
-2 msec
0 0 0 1 1
-3 msec
0 0 1 0 0
-4 msec
:
:
0 1 1 1 0
-14 msec
0 1 1 1 1
-15 msec
Usage/Comments
Time
0 0 0 0 0 0 0 0
30 ms
0 0 0 0 0 0 0 1
20 ms
0 0 0 0 0 0 1 0
40 ms
0 0 0 0 0 0 1 1
60 ms
0 0 0 0 0 1 0 0
80 ms
1 1 1 1 1 1 1 0
5080 ms
1 1 1 1 1 1 1 1
5100 ms
Initial setting
Initial setting