Memory Switch C:1 - Reception
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Received document length
limit
0: No limit
1: 3 m (9.8 feet)
4
0
T1 timer
0: 35 sec
1: 20 sec
3
1
Print image data when post
message is not received after
receiving RTC signal
0: No
1: Yes
2
0
Disable ITU-T superfine
reception
0: Yes
1: No
1
0
G3 echo receive
Adjusts the delay between detection of training/TCF and sending of CFR.
0
1
Switch 1
Switch 0
Memory Switch C:2
Adjust
Set the limit of received document length.
Adjusts the T1 time-out. After the machine dials the
remote machine's phone number, it begins sending
CNG and waits this amount of time before
disconnecting the line.
If the received document includes the RTC, the
machine prints the data even though the following
protocol is not succeeded.
Set to "1" if a compatibility error occurs because the
transmitting machine does not understand the
extended frame for ITU-T superfine resolution.
(Note: Setting this switch to "1" will disable superfine
mode.)
100 ms 500 ms 800 ms 1200 ms
0
0
1
0
1
0