6.7.2.2 ADJUSTMENT

6.7.2.2.1 Adjustment of Printer Registration (side)
Requirement:
First perform the adjustments listed below:
1. Printer registration (top) and Printer registration (side) for all paper sources. (See page 5-81 and 5-82.)
2. ADF registration (top and side) and FBS registration (top and side). (See page 5-83 and 5-84.)
Dimension A on the 2-sided copy should be adjusted to meet specifications.
Specification
10 ± 2.0 (mm)
Adjustment procedure
1. Load the A3-sized paper to the cassette.
2. Produce a test pattern D with the A3-sized paper and make a 2-sided copy of it.
(To produce a test pattern D, press MENU, [, 9, Test Pattern Print. For detail, see page 3-123.)
3. Check to see if width A meets the specifications.
If width A falls outside the specified range, perform following steps to make the adjustment.
4. Entry the Machine Parameter mode. (Press MENU, [, 0. For detail, see page 3-2.)
5. Adjust the setting of Machine Parameter K:7 to meet the specification.
If the width A is shorter than specification, increase value.
If the width A is longer than specification, decrease value.
A
Adjustment Tool
Machine parameter K:7
Machine parameter L:7
6-85
A
Test pattern D
Setting Range
– 12.8 to 12.7 (mm)
(0.1 mm step)