Diagnostics
20
Beaconing is enabled for the port.
1. Consult the customer and next level of support to determine the reason port
2. Disable port beaconing.
Was port beaconing enabled because port failure or degradation was suspected?
YES
Go to
21
As indicated by a message or event code 080, the eight-byte (16-digit) worldwide
name (WWN) entered to configure port binding is not valid or a nickname was
used that is not configured for the attached device in the Element Manager
application.
From the Hardware View, click Node List. Note the Port WWN column. This is
the WWN assigned to the port or Fibre Channel interface installed on the attached
device.
The bound WWN must be entered in the form of a raw WWN format
(XX:XX:XX:XX:XX:XX:XX:XX) or must be a valid nickname. Ensure a valid
WWN or nickname is entered.
Did configuring the WWN or nickname solve the problem?
NO
Contact the next level of support. Exit MAP.
100
beaconing is enabled.
a. At the Hardware View, right-click the port graphic. A pop-up menu
appears.
b. Click the Enable Beaconing option. The check mark disappears from the
box adjacent to the option, and port beaconing is disabled.
NO
The switch appears operational. Exit MAP.
step
1.
If a nickname is not assigned to the WWN, the WWN is prefixed by the
device manufacturer's name.
If a nickname is assigned to the WWN, the nickname appears in place of the
WWN.
YES
The switch appears operational. Exit MAP.