Repair Information
156
Type—The Port type (G_Port, F_Port, or E_Port) type of port (G_Port if
nothing is attached to the port, F_Port if a device is attached to the port, and
E_Port if the port is connected to another director or switch as part of an ISL).
Operating Speed—The operating speed of the port (Not Established,
1 Gb/s, or 2 Gb/s.).
Port WWN—The Fibre Channel WWN for the switch port.
Block Configuration—A user-configured state for the port (Blocked or
Unblocked).
LIN Alerts Configuration—A user-specified state for the port
(On or Off), configured through the Configure Ports dialog box.
FAN Configuration—A user-configured state for FAN configuration
(Enabled or Disabled).
Beaconing—User-specified for the port (On or Off). When beaconing is
enabled, a yellow triangle appears adjacent to the status field.
Link Incident—If no link incidents are recorded, None appears in the status
field. If a link incident is recorded, a summary appears describing the
incident, and a yellow triangle appears adjacent to the status field. Valid
summaries are:
— Implicit incident.
— Bit-error threshold exceeded.
— Link failure–loss of signal or loss of synchronization.
— Link failure–not-operational primitive sequence received.
— Link failure–primitive sequence time-out.
— Link failure–invalid primitive sequence received for the current link state.
Operational State—The state of the port (Online, Offline, Beaconing,
Invalid Attachment, Link Incident, Link Reset, No Light, Not
Operational, Port Failure, Segmented E_Port, or Testing). A yellow
triangle appears adjacent to the status field if the port is in a non-standard state
that requires attention. A red and yellow diamond appears adjacent to the
status field if the port fails.
Reason—A summary appears describing the reason if the port state is
Segmented E_Port, Invalid Attachment, or Inactive. For any other port
state, the reason field is blank or N/A. Invalid Attachment Messages are
explained in
Table
23.