Table 76: Event Code 411
Message:
Firmware fault.
Severity:
Major.
Explanation:
Switch firmware encountered an unexpected condition and dumped operating state
information to FLASH memory for retrieval and analysis. The dump file
automatically transfers from the switch to the HAFM appliance, where it is stored
for later retrieval through the data collection procedure.
The switch performs a software reset, during which all attached Fibre Channel
devices are momentarily disrupted, log out, and log back in.
Action:
Perform the data collection procedure and return the backup disk to
Hewlett-Packard support personnel.
Event Data:
Bytes 0 through 3 = fault identifier, least significant byte first.
Distribution:
Switch
EWS
Event
Log
Table 77: Event Code: 412
Message:
CTP watchdog timer reset.
Severity:
Informational.
Explanation:
The hardware watchdog timer expired and caused the CTP card to reset.
Action:
Perform the data collection procedure and return the backup disk to HP support
personnel.
Event Data:
Byte 0 = reset type as follows:
00 = task switch did not occur within approximately one second,
01 = interrupt servicing blocked for more than approximately one second.
Distribution:
Switch
EWS
Event Log
Edge Switch 2/24 Service Manual
HAFM Appliance
System
Event
Error
Log
LED
HAFM Appliance
System
Event Log
Error LED
E-Mail
Call
Home
E-Mail
Call-Home
Event Codes
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident
281

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents