HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 267

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 service manual (aa-rtdxc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Table 83: Event Code 432
Message:
Ethernet adapter reset.
Severity:
Minor.
Explanation:
The CTP card Ethernet adapter was reset in response to an internally detected error.
A card failure is not indicated. The switch-to-HAFM appliance connection
terminates, but automatically recovers after the reset.
Action:
Perform the data collection procedure and return the backup disk to HP support
personnel.
Event Data:
Bytes 0 through 3 = reason for adapter reset, least significant byte first
(reset_error_type) 1 = completion notification for timed-out frame transmission.
Distribution:
Switch
EWS
Event Log
Table 84: Event Code 433
Message:
Non-recoverable Ethernet fault.
Severity:
Major.
Explanation:
A non-recoverable Ethernet interface failure was detected and the LAN connection
to the HAFM appliance or Internet was terminated. No failure information or event
codes are reported outside the switch. Although Fibre Channel port functionality is
not affected, the switch cannot be monitored or configured.
Action:
Replace the switch.
Event Data:
Byte 0 = LAN error type as follows: 01 = hard failure, 04 = registered fault.
Byte 1 = LAN error subtype (internally defined).
Byte 2 = LAN fault identifier (internally defined).
Distribution:
Switch
EWS
Event
Log
Edge Switch 2/24 Service Manual
HAFM Appliance
System
Event Log
Error LED
HAFM Appliance
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
Event Codes
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident
285

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents