HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 89

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 service manual (aa-rtdxc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

11
Is fault isolation being performed at the EWS interface?
YES
12
Does the EWS interface appear operational?
NO
13
A Page cannot be found, Unable to locate the server,
HTTP 404 - file not found, or other similar message appears. The
message indicates the PC cannot communicate with the switch because:
The EWS interface is not operational and fault isolation must be performed at the
switch or HAFM appliance. Go to
contact the next level of support. Exit MAP.
14
Inspect fan module operational states at the EWS interface.
1. At the View panel, click the FRU Properties tab. The View panel (FRU
2. Inspect the Status fields for both power supplies.
Does the Status field display a Failed message for either fan module?
NO
15
Inspect switch CTP operational states at the EWS interface. Inspect the Status
fields for the switch CTP.
Edge Switch 2/24 Service Manual
NO
Fault isolation is being performed at the HAFM appliance. Go to
step
16.
YES
Go to
step
14.
The switch-to-PC Internet link could not be established.
AC power distribution in the switch failed, or AC power was disconnected.
The switch CTP card failed.
Properties tab) displays.
YES
A fan module failure is indicated. Go to
step
1. If this is the second time at this step,
step
Diagnostics
6.
91