HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 72

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 service manual (aa-rtdxc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Diagnostics
3
A Page cannot be found, Unable to locate the server,
HTTP 404 - file not found, or other similar message appears. The
message indicates the PC cannot communicate with the switch because:
Continue to the next step.
4
Ensure the switch is connected to facility AC power. Inspect the switch for
indications of being powered on, such as:
Does the switch appear powered on?
YES
5
At the front of the switch, inspect the amber ERR LED.
Is the LED illuminated?
NO
6
Either a switch-to-PC Internet link problem (Internet too busy or IP address typed
incorrectly) or a switch Ethernet port failure is indicated.
1. Wait approximately five minutes, then attempt to login to the switch again.
74
The switch-to-PC Internet (Ethernet) link could not be established.
AC power distribution in the switch failed, or AC power was disconnected.
The switch CTP card failed.
At the front bezel, an illuminated PWR LED (green) or ERR LED (amber).
Illuminated LEDs adjacent to Fibre Channel ports.
Audio emanations and airflow from cooling fans.
NO
A power distribution problem is indicated. Go to
Distribution
YES
A FRU failure or link incident is indicated. Go to
MAP" on page 32. Exit MAP.
Analysis" on page 54. Exit MAP.
"MAP 0100: Power
"MAP 0000: Start
Edge Switch 2/24 Service Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents