HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 53

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 service manual (aa-rtdxc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

2. At the HAFM appliance Hardware View, observe the graphic representing
Is a failure indicated?
YES
8
Visual inspection or an event code 200 or 201 indicates one or both power
supplies must be removed and replaced. Refer to
Supply" on page 198.
Did power supply replacement solve the problem?
NO
Contact the next level of support. Exit MAP.
9
Is fault isolation being performed at the switch?
YES
Edge Switch 2/24 Service Manual
the power supply and ensure a failure symbol (blinking red and yellow
diamond) does not appear.
NO
The switch appears operational. Exit MAP.
This procedure is concurrent and can be performed while switch power is on.
Perform the data collection procedure as part of FRU removal and
replacement.
If multiple power supply failures occurred, connect the switch to facility AC
power after both power supplies are replaced.
Caution:
Do not remove a power supply unless a replacement FRU is
immediately available. To avoid product overheating, a removed power supply
must be replaced within five minutes.
YES
The switch appears operational. Exit MAP.
NO
Fault isolation is being performed at the EWS interface or HAFM
appliance. Go to
"RRP: Redundant Power
step
18.
Diagnostics
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32