Table 4: Event Codes versus Maintenance Action (Continued)
Event
Code
310
311
312
313
314
315
400
410
411
412
421
423
426
433
440
442
445
453
506
507
508
Edge Switch 2/24 Service Manual
Explanation
Cooling fan propeller recovered.
Cooling fan propeller recovered.
Cooling fan propeller recovered.
Cooling fan propeller recovered.
Cooling fan propeller recovered.
Cooling fan propeller recovered.
Power-up diagnostic failure.
Switch reset.
Firmware fault.
CTP watchdog timer reset.
Firmware download complete.
CTP firmware download initiated.
Multiple ECC single-bit errors occurred.
Non-recoverable Ethernet fault.
Embedded port hardware failed.
Embedded port anomaly detected.
ASIC detected a system anomaly.
New feature key installed.
Fibre Channel port failure.
Loopback diagnostics port failure.
Fibre Channel port anomaly detected.
Diagnostics
Action
No action required.
No action required.
No action required.
No action required.
No action required.
No action required.
Go to
MAP 0200: POST
Failure
Analysis.
No action required.
Go to
MAP 0200: POST
Failure
Analysis.
Go to
"Collecting
Maintenance Data" on
page
165.
No action required.
No action required.
Go to
MAP 0500: FRU
Failure
Analysis.
Go to
MAP 0500: FRU
Failure
Analysis.
Go to
MAP 0500: FRU
Failure
Analysis.
No action required.
No action required.
No action required.
Go to
MAP 0600: Port
Failure and Link Incident
Analysis.
Go to
MAP 0600: Port
Failure and Link Incident
Analysis.
No action required.