Event Codes
Table 95: Event Code 513
Message:
SFP optical transceiver hot-removal completed.
Severity:
Informational.
Explanation:
An SFP optical transceiver was removed while the switch was powered on and
operational.
Action:
No action required.
Event Data:
Byte 0 = port number (00 through 23).
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution:
Switch
EWS
Event
Log
Table 96: Event Code 514
Message:
SFP optical transceiver failure.
Severity:
Major.
Explanation:
An SFP optical transceiver failed. The amber LED corresponding to the port
illuminates to indicate the failure. Other ports remain operational if their LEDs are
extinguished.
Action:
Replace the failed transceiver with a functional transceiver of the same type.
Event Data:
Byte 0 = port number (00 through 23).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution:
Switch
EWS
Event
Log
292
HAFM Appliance
System
Event
Error
Log
LED
HAFM Appliance
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
Edge Switch 2/24 Service Manual
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents