HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 238

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 service manual (aa-rtdxc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Event Codes
Table 39: Event Code 070 (Continued)
Event Data:
The first byte of event data (byte 0) specifies the E_Port number. The fifth byte (byte
4) specifies the segmentation reason as follows:
1 = Incompatible operating parameters. Ether the resource allocation time out
value (R_A_TOV) or error detect time out value (E_D_TOV) is inconsistent between
the switch and another fabric element (Director or Edge Switch). Modify the
R_A_TOV and E_D_TOV to make the values consistent for all fabric Directors and
Edge Switches.
2 = Duplicate domain ID. The switch has the same preferred domain ID as another
fabric element (Director or Edge Switch). Modify the switch Domain ID to make it
unique.
3 = Incompatible zoning configurations. The same name is applied to a zone for
the switch and another fabric element (Director or Edge Switch), but the zones
contain different zone members. Modify the zone name to make it unique, or
ensure zones with the same name contain identical zone members.
4 = Build fabric protocol error. A protocol error was detected during incorporation
of the switch into the fabric. Disconnect the E_Port link, reconnect the link, and
initial program load (IPL) the switch. If the condition persists, perform the data
collection procedure and return the backup disk to Hewlett-Packard support
personnel.
5 = No principal switch. No Director or Edge Switch in the fabric can become the
principal switch. Modify the switch priority to any value other than 255.
6 = No response from attached switch (hello timeout). The switch periodically
verifies operation of attached fabric elements (Director or Edge Switch). The switch
E_Port (at the operational switch) times out and segments if the attached device
does not respond. Check the status of the attached Director or Edge Switch. If the
condition persists, perform the data collection procedure (at the attached device)
and return the backup disk to Hewlett-Packard support personnel.
256
Edge Switch 2/24 Service Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents