HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 93

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 service manual (aa-rtdxc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

6
As indicated by a message or event code 506, 512, or 514, a Fibre Channel port
failed and the SFP optical transceiver must be removed and replaced. Refer to
"RRP: SFP Optical
Did optical transceiver replacement solve the problem?
NO
Contact the next level of support. Exit MAP.
7
Is fault isolation being performed at the EWS interface?
YES
8
Does the EWS interface appear operational?
NO
9
A Page cannot be found, Unable to locate the server,
HTTP 404 - file not found, or other similar message appears. The
message indicates the PC cannot communicate with the switch because:
Edge Switch 2/24 Service Manual
Transceiver" on page 195.
This procedure is concurrent and can be performed while the switch is
powered on and operational.
Verify location of the failed port.
Replace the optical transceiver with a transceiver of the same type (shortwave
or longwave).
Perform an external loopback test for the port as part of FRU removal and
replacement. Refer to
YES
The switch appears operational. Exit MAP.
NO
Fault isolation is being performed at the HAFM appliance. Go to
step
13.
YES
Go to
step
11.
The switch-to-PC Internet link could not be established.
AC power distribution in the switch failed, or AC power was disconnected.
"Perform Loopback
Tests" on page 160.
Diagnostics
95