35
Inspect the fiber-optic jumper cable attached to the port and ensure the cable is not
bent and connectors are not damaged. If the cable is bent or connectors are
damaged:
1. Notify the customer the port will be blocked. Ensure the customer's system
2. Block the port. Refer to
3. Remove and replace the fiber-optic jumper cable.
4. Unblock the port. Refer to
Was a corrective action performed?
YES
36
Monitor port operation for approximately five minutes.
Did the link incident recur?
YES
37
Clean fiber-optic connectors on the jumper cable.
1. Notify the customer the port will be blocked. Ensure the customer's system
2. Block the port. Refer to
3. Disconnect both ends of the fiber-optic cable.
4. Clean the fiber-optic connectors. Refer to
5. Reconnect the fiber-optic cable.
6. Unblock the port. Refer to
7. Monitor port operation for approximately five minutes.
Edge Switch 2/24 Service Manual
administrator quiesces Fibre Channel frame traffic through the port and sets
the attached device offline.
NO
Go to
step
37.
NO
The Fibre Channel link and switch appear operational. Exit MAP.
administrator quiesces Fibre Channel frame traffic through the port and sets
the attached device offline.
page 171.
"Clean Fiber-Optic
Components" on page 167.
"Clean Fiber-Optic
"Clean Fiber-Optic
Components" on page 167.
"IML, IPL or Reset the
"Clean Fiber-Optic
Components" on page 167.
Switch" on
Components" on page 167.
Diagnostics
109