Event Codes
Table 59: Event Code 206
Message:
Power supply removed.
Severity:
Informational.
Explanation:
A power supply was removed while the Switch was powered on and operational.
The second power supply assumes the full operating load for the switch.
Action:
No action required or install an operational power supply.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EWS
Event
Log
Table 60: Event Code 207
Message:
Power supply installed.
Severity:
Informational.
Explanation:
A redundant power supply was installed with the switch powered on and
operational. Both power supplies adjust to share operating load for the switch.
Action:
No action required.
Event Data:
No supplementary data included with the event.
Distribution:
Switch
EWS
Event
Log
Table 61: Event Code 208
Message:
Power supply false shutdown.
Severity:
Major.
Explanation:
Switch operational firmware nearly shut down the indicated power supply as a result
of failure or facility power loss or voltage fluctuation.
Action:
Confirm operation of facility power. If subsequent power loss events occur, replace
the failed power supply. Perform the data collection procedure and return the
backup disk and failed power supply to HP support personnel.
272
HAFM Appliance
System
Event
Error
Log
LED
HAFM Appliance
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
Edge Switch 2/24 Service Manual
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents