Table 108: Event Code 812
Message:
CTP card shutdown due to thermal violation.
Severity:
Major.
Explanation:
A CTP failed and was powered off because of excessive heat. This event follows an
indication that the hot temperature threshold was reached or exceeded (event code
811).
Action:
Replace the failed switch. Perform the data collection procedure and return the
backup disk and faulty switch to HP support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EWS
Event Log
Table 109: Event Code 850
Message:
System shutdown due to CTP card thermal violations.
Severity:
Severe.
Explanation:
The switch powered off because of excessive thermal violations on the CTP card.
Action:
Replace the failed switch. Perform the data collection procedure and return the
backup disk and faulty switch to HP support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EWS
Event Log
Edge Switch 2/24 Service Manual
HAFM Appliance
System
Event Log
Error LED
HAFM Appliance
System
Event Log
Error LED
E-Mail
Call
Home
E-Mail
Call
Home
Event Codes
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident
299

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents