HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 278

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 service manual (aa-rtdxc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Event Codes
Table 103: Event Code 584
Message:
Not operational primitive sequence received.
Severity:
Major.
Explanation:
An attached OSI server received a not-operational primitive sequence (NOS).
Action:
An LIR is generated and sent to the attached server using the reporting procedure
defined in T11/99-017v0 (OSI). If fault isolation at the server does not detect a
failure, the problem may be due to a port failure. Go to
on page 32 to perform fault isolation.
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution:
Switch
EWS
Event
Log
Table 104: Event Code 585
Message:
Primitive sequence timeout.
Severity:
Major.
Explanation:
An attached OSI server recognized either a link reset (LR) protocol timeout or a
timeout while waiting for the appropriate response (while in a NOS receive state
and after NOS was not longer recognized).
Action:
An LIR is generated and sent to the attached server using the reporting procedure
defined in T11/99-017v0 (OSI). If fault isolation at the server does not detect a
failure, the problem may be due to a port failure. Go to
on page 32 to perform fault isolation.
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution:
Switch
EWS
Event
Log
296
HAFM Appliance
System
Event
Error
Log
LED
HAFM Appliance
System
Event
Error
Log
LED
"MAP 0000: Start
E-Mail
Call
Home
"MAP 0000: Start
E-Mail
Call
Home
Edge Switch 2/24 Service Manual
MAP"
Host
Sense
Link
Info
Incident
MAP"
Host
Sense
Link
Info
Incident

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents