A switch-to-HAFM appliance Ethernet link failure is indicated.
Go to
0400: Loss of Server
28
Is a red diamond (failure indicator) associated with the icon representing the
switch reporting the problem?
YES
29
Right-click the icon representing the switch reporting the problem. A pop-up
menu appears. Click the Element Manager option from the menu. The Element
Manager application opens and the Hardware View displays.
At the Hardware View:
Do blinking red and yellow diamonds overlay any FRU graphics?
NO
30
Is a yellow triangle (attention indicator) associated with the icon representing the
switch reporting the problem?
YES
Edge Switch 2/24 Service Manual
A FRU failure or link incident is indicated. Go to
event codes that identify the failure. Exit MAP.
step 38
to obtain event codes. If no event codes are found, go to
Communication" on page 75. Exit MAP.
NO
Go to
step
30.
Observe that the Edge Switch Status table is yellow and the switch status is
NOT OPERATIONAL.
Inspect FRUs for a blinking red and yellow diamond (failed FRU indicator)
that overlays the FRU graphic.
YES
Failure of one or more FRUs is indicated. Go to
event codes. If no event codes are found, go to
Failure
Analysis" on page 89. Exit MAP.
NO
Go to
step
33.
Diagnostics
step 38
to obtain
"MAP
step 38
to obtain
"MAP 0500: FRU
43