HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 151

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 service manual (aa-rtdxc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Note:
unblocked.
2. Open the HAFM application. The View All - HAFM 8 main window displays.
3. At the HAFM physical map, right-click the product icon representing the
4. Disconnect the fiber-optic jumper cable from the port.
5. Depending on the port technology, insert a singlemode or multimode
6. Click Maintenance > Port Diagnostics. The Port Diagnostics dialog box
7. Type the port number to be tested or select all ports at the Port Select area of
8. At the Diagnostics Test list box, select the External Loopback option.
9. Click Next. At the Port Diagnostics dialog box, the message Loopback
10. Verify a loopback plug is installed and click Next. The message Press
11. Click Start Test. The test begins and:
Note:
12. When the test completes, results appear as Port xx: Passed! or Port
13. When finished, click Cancel to close the Port Diagnostics dialog box.
Edge Switch 2/24 Service Manual
At the start of the loopback test, the port can be online, offline, blocked, or
switch to be tested, then click Element Manager from the pop-up menu. The
application opens.
loopback plug into the port receptacle.
displays.
the dialog box.
plug(s) must be installed on ports being diagnosed
displays.
START TEST to begin diagnostics displays, and the Next button
changes to a Start Test button.
— The Start Test button changes to a Stop Test button.
— The message Port xx: TEST RUNNING displays.
— A red progress bar (indicating percent completion) travels from left to
right across the Completion Status field.
Click Stop Test at any time to abort the loopback test.
xx: Failed! in the message area of the dialog box.
Repair Information
161