HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 94

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 service manual (aa-rtdxc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Diagnostics
Continue to the next step.
10
Ensure the switch is connected to facility AC power. Inspect the switch for
indications of being powered on, such as:
Does the switch appear powered on?
YES
11
Inspect Fibre Channel port operational states at the EWS interface.
1. At the View panel, click the Port Properties tab. The View panel (Port
2. Click the port number (0 through 23) for which a failure is suspected to
3. Inspect the Operational State field. Scroll down the View panel as necessary.
4.
Table 11: Port Operational States and Actions (EWS)
Operational State
Offline
Not Operational
Port Failure
Testing
96
The switch CTP card failed.
At the front bezel, an illuminated PWR LED (green) or ERR LED (amber).
Illuminated LEDs adjacent to Fibre Channel ports.
Audio emanations and airflow from cooling fans.
NO
Analysis for an Ethernet link, AC power distribution, or CTP failure
is not described in this MAP. Go to
page 32. If this is the second time at this step, contact the next level of
support. Exit MAP.
Properties tab) displays with port 0 highlighted in red.
display properties for that port.
Table 13
lists port operational states and MAP 0600 steps that describe fault
isolation procedures.
Go to
step
19.
Go to
step
19.
Go to
step
6.
Internal or external loopback test in process. Exit MAP.
"MAP 0000: Start
MAP" on
Action
Edge Switch 2/24 Service Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents