Syntax
<
>
rollback
number
Options
— Return to the most recently saved configuration.
none
number
—Configuration to return to.
Range: 0 through 49. The most recently saved configuration is number 0, and the
oldest saved configuration is number 49.
Default: 0
To return to a configuration prior to the most recently committed one:
Specify the rollback number (here, 1 is entered and the configuration returns to the
1.
previously committed configuation):
[edit]
user@switch# rollback 1
load complete
Activate the configuration you have loaded:
2.
[edit]
user@switch# commit
Managing Configuration Files Through the Configuration History (J-Web Procedure)
on page 412
Configuration Files Terms on page 382
For more information on rollback, see the Junos OS CLI User Guide.
If for any reason the current active configuration fails, you can revert to the default factory
configuration. You can also roll back to a previous configuration, as described in "Loading
a Previous Configuration File (CLI Procedure)" on page 414, or revert to the rescue
configuration, as described in "Reverting to the Rescue Configuration for the EX Series
Switch" on page 417.
The default factory configuration contains the basic configuration settings. This is the
first configuration of the switch and it is loaded when the switch is first installed and
powered on.
You can revert to the default factory configuration by using the
of the LCD on the front panel of the switch or by using the
configuration command.
Reverting to the Default Factory Configuration by Using the LCD Panel on page 416
Reverting to the Default Factory Configuration by Using the Load Factory Default
Command on page 416