Quick Programming Mode

In quick programming mode the basic parameters required for the elevator operation like speeds, acceleration/
deceleration times etc. can be monitored and set.
The parameters can be changed from the setting displays. Use the Increment, Decrement, and Shift/RESET
keys to change the frequency. The parameter is written and the display returns to the monitor display when the
DATA/ENTER key is pressed.
Refer to
page 5-4, User Parameters Available in Quick Programming Mode
Example Operations
Example key operations in quick programming mode are shown in the following figure.
Mode Selection Display
3
-
DRIVE-
** Main Menu **
-QUICK-
** Main Menu **
Quick Setting
-
ADV-
** Main Menu **
Programming
-VERIFY-
** Main Menu **
Modified Consts
-A.TUNE-
** Main Menu **
Auto-Tuning
8
3-
MENU
Operation
MENU
ESC
MENU
MENU
MENU
Fig 3.6 Operations in Quick Programming Mode
Monitor Display
A
B
-QUICK-
Control Method
A1-02 =
0
*0*
V/f Control
"0"
ESC
-QUICK-
Accel Time 1
C1-01 = 1.50sec
(0.00 ~ 600.00)
"1.50"
ESC
-QUICK-
Decel Time 1
C1-02 = 1.50sec
(0.00 ~ 600.00)
"1.50"
ESC
-QUICK-
Mtr Rated Power
E2-11 = 4.00kW
(0.00 ~ 650.00)
"4.00kW"
ESC
-QUICK-
MOL Fault Select
L1-01=1
*1*
Std Fan Cooled
"1"
ESC
A
B
for details.
Setting Display
-QUICK-
Control Method
A1-02 =
0
*0*
V/f Control
"0"
-QUICK-
Accel Time 1
C1-01 =001.50sec
(0.00 ~ 600.00)
"1.50"
-QUICK-
Decel Time 1
C1-02 =001.50sec
(0.00 ~ 600.00)
"1.50"
-QUICK-
Mtr Rated Power
E2-11 = 004.00kW
(0.00 ~ 650.00)
"4.00kW"
-QUICK-
MOL Fault Select
L1-01 =
1
*1*
Std Fan Cooled
"1"