Limiting the Motor Torque (Torque Limit Function)

This function allows limitation of motor shaft torque independently for each of the four quadrants. The torque
limit can be set as a fixed value using parameters or as a variable value using an analog input. The torque limit
function can be used with Open Loop Vector and Closed Loop Vector control only.
Related Parameters
Parameter No.
L7-01
Forward drive torque limit
L7-02
Reverse drive torque limit
L7-03
Forward regenerative torque limit
L7-04
Reverse regenerative torque limit
L7-06
Torque limit integral time constant
Torque limit integral operation during accel./
L7-07
decel. selection
* A setting value of 100% is equal to the motor rated torque.
Multi-function Output (H2-01 to H2-03)
Set
Value
30
During torque limit
Setting the Torque Limit Using Parameters
Using L7-01 to L7-04, four torque limits in the following directions can be set individually: Forward drive,
reverse drive, forward regenerative and reverse regenerative (see
Using a Digital Output to Signalize Operation at the Torque Limit
If a multifunction output is set to this function (H2-01 to H2-03 is set to "30"), the output is switched ON
when the motor output torque reaches one of the torque limits.
Factory Set-
Name
ting
300%*
300%*
300%*
300%*
200 ms
0
Function
Output Torque
L7-01
L7-04
Forward
Reverse
Drive
Regenerative
Forward
Reverse
Regenerative
Drive
L7-03
L7-02
Fig 6.18 Torque Limit Parameters
Control Methods
Change dur-
Open
ing Opera-
V/f
Loop
tion
Vector
No
-
A
No
-
A
No
-
A
No
-
A
No
-
A
No
-
A
Control Methods
Open
Closed
V/f
Loop
Vector
Vector
No
Yes
Fig
6.18)
Output Speed
Closed
Closed
Loop
Loop
Vector
Vector
(PM)
A
A
A
A
A
A
A
A
-
-
-
-
Closed
Loop
Loop
Vector
(PM)
6
Yes
Yes
43
6-