Name
Para-
meter
Num-
Display
ber
DC injection
braking/ Zero
speed time at
S1-05
stop
DC Inj T@stop
Brake release
delay time
S1-06
Brake open
delay
Brake close
delay time
S1-07
Brake CloseDe-
lay
SE2 detection
delay time
5
S1-14
SE2 det T
SE3 detection
delay time
S1-15
SE3 det T
RUN delay
time
S1-16
Run Delay T
DC injection
current gain at
regenerative
S1-17
operation
DC Inj
gain@gen
DC injection
current gain at
motoring oper-
S1-18
ation
DC Inj
gain@mot
Output contac-
tor open delay
time
S1-19
Cont open
delay
48
5-
Description
Used to set the time to perform DC
injection braking at stop in units of
1 second.
Used to prevent coasting after the
stop command is input. When the
set value is 0.00, DC injection
braking at stop is not performed.
Sets the time delay from the brake
open command to the start of
acceleration.
This timer can be used to avoid
running against the closed brake at
start.
Sets the time delay from the inter-
nal brake close command until the
brake control output is switched.
This timer can be used to avoid
closing the brake when the motor is
still turning.
Used to set the delay time for the
detection of a SE2 fault.
At the time S1-06 + S1-14 after the
Fwd/Rev command was given the
output current is measured. If it is
below 25% of the no-load current
(E2-03) setting a SE2 fault will be
output.
Used to set the delay time for the
detection of a SE3 fault.
At the time S1-15 after the fwd/rev
command was given, the inverter
starts to observe the output current
continuously. If it falls below 25%
of the no-load current (E2-03) set-
ting a SE3 will be output.
Sets the delay time from the Run
signal input to the internal run
enable.
Used to set the DC injection gain
when inverter is in the regenerative
mode.
Used to set the DC injection gain
when inverter is in the motoring
mode.
Sets the contactor control output
delay time after stop.
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
tion
0.00
to
0.60 s
No
A
10.00
0.00
to
0.20
No
A
10.00
0.00
to
0.10
No
A
S1-05
0
to
200ms
No
A
S1-04 -
S1-06
0
to
200ms
No
A
5000
0.00
to
0.10sec
No
A
1.00
0
to
100%
No
-
400
0
to
20%
No
-
400
0.00
to
0.10sec
No
A
1.00
Control Methods
MEMO-
Closed
Open
Closed
BUS
Loop
Loop
Loop
Register
Vector
Vector
Vector
(PM)
A
A
A
684H
A
A
A
685H
A
A
A
686H
A
A
-
68DH
A
A
-
68EH
A
A
A
68FH
A
-
-
690H
A
-
-
691H
A
A
A
692H
Page
6-13
6-13
6-13
6-46
6-46
6-13
6-39
6-39
6-13