Omron VARISPEED L7 Manual page 94

Hide thumbs Also See for VARISPEED L7:
Table of Contents

Advertisement

Name
Param-
eter
Num-
Display
ber
Motor rated output
Sets the rated output power of the
power
motor.
E2-11
This parameter is an input data for auto-
Mtr Rated Power
tuning.
Motor rated output
Sets the rated output power of the
power
E5-02
motor.
Rated Power
Rated Motor Cur-
rent
E5-03
Sets the rated motor current.
Rated Current
Number of motor
poles
E5-04
Sets the motor pole number.
Number of poles
Motor terminal
resistance
E5-05
Sets the motor line-to-line resistance
Term resistance
d-Axis Inductance
E5-06
Sets the D-axis inductance.
d-ax inductance
q-Axis Inductance
E5-07
Sets the Q-axis inductance.
q-ax inductance
Motor voltage con-
stant
E5-09
Sets the voltage constant of the motor.
Voltage constant
PG constant
Sets the number of PG pulses per revo-
F1-01
lution
PG Pulses/Rev
0: Phase A leads with forward run com-
PG rotation
mand. (Phase B leads with reverse run
command.)
F1-05
1: Phase B leads with forward run com-
mand. (Phase A leads with reverse
PG Rotation Sel
run command.)
Set to enable or disable the motor over-
load protection function using the elec-
Motor protection
tronic thermal relay.
selection
0: Disabled
1: Protection for general purpose motor
(fan cooled)
L1-01
2: Protection for frequency converter
motor (external cooled)
3: Protection for special vector control
MOL Select
motor
5: Permanent magnet constant torque
motor
Sets the detection method for magnetic
Magnetic pole
pole position of a PM motor.
position detection
0: Automatic detection (applicable for
n8-35
Yaskawa IPM motor only)
4: Hiperface y Data
Mag det sel
5: EnDat Data
*1. The setting ranges for acceleration/deceleration times depends on the setting of C1-10 (Acceleration/deceleration Time Setting Unit). If C1-10 is set to 0,
the setting range is 0.00 to 600.00 (s).
*2. The given values are for a 400 V class Inverter.
*3. The setting range is from 10% to 200% of the Inverter rated output current. The given values are for a 3.7 kW 400 V Class Inverter.
*4. The factory setting depends on the Inverter capacity. The given value is for a 3.7 kW 400 V Class Inverter.
Setting
Description
Range
0.00 to
650.00
0.00 to
300.00
0.00 to
200.00
4 to 48
0.000
to
65.000
0.00 to
300.00
0.00 to
600.00
50.0 to
4000.0
0 to
60000
0 or 1
0 to 3
0 or 5
0, 4 or
5
Control Methods
Change
Factory
during
Open
Setting
Opera-
V/f
Loop
tion
Vector
3.70
kW
No
Yes
Yes
*4
3.70
kW
No
-
-
*4
7.31
No
-
-
*4
A
4
No
-
-
1.326
No
-
-
*4
Ohm
19.11
mH
No
-
-
*4
26.08
mH
No
-
-
*4
478.6
mV
No
-
-
*4
i
No
-
-
i
No
-
-
1
Yes
Yes
No
5
5
No
-
-
MEMO
Closed
BUS
Closed
Loop
Regis-
Loop
Vector
ter
Vector
(PM)
Yes
No
318H
-
Yes
0C2H
-
Yes
0C3H
-
Yes
0C4H
-
Yes
0C5H
-
Yes
0C6H
-
Yes
0C7H
5
-
Yes
0C9H
Yes
-
1024
380H
Yes
-
2048
0
-
384H
-
1
Yes
-
480H
Yes
-
Yes
192H
5-
7