Name
Param-
eter
Num-
Display
ber
Output terminal
status
U1-11
Output Term Sts
Operation status
U1-12
5
Int Ctl Sts 1
Cumulative
operation time
U1-13
Elapsed Time
Software No.
(flash memory)
U1-14
FLASH ID
Terminal A1
input level
U1-15
Term A1 Level
AI-14B channel
2 input level
U1-16
*1
AI-14 Ch2
InpLvl
AI-14B channel
3 input level
U1-17
*1
AI-14 Ch3
InpLvl
Motor second-
ary current (Iq)
U1-18
Mot SEC Cur-
rent
Motor excita-
tion current (Id)
U1-19
Mot EXC cur-
rent
56
5-
Description
Multi-Function Analog Output
Shows output ON/OFF status.
1: Multi-function
contact output 1
(M1-M2) is ON
1: Multi-function
contact output 2
(M3-M4) is ON
1: Multi-function
contact output 3
(Cannot be output.)
(M5-M6) is ON
Not used
(Always 0).
1: Error output
(MA/MB-MC) is
ON
Inverter operating status.
Run
1: Zero speed
1: Reverse
1: Reset signal
input
1: Speed agree
1: Inverter ready
(Cannot be output.)
1: Minor fault
1: Major fault
Monitors the total operating
time of the Inverter.
The initial value and the operat-
(Cannot be output.)
ing time/power ON time selec-
tion can be set in o2-07 and o2-
08.
(Manufacturer's ID number)
(Cannot be output.)
Monitors the input level of ana-
10 V: 100%
log input A1. A value of 100%
(0 to ± 10 V possible)
corresponds to 10V input.
Monitors the input level of ana-
log input 2 on a AI-14B option
10 V: 100%
board. A value of 100% is equal
(0 to ± 10 V possible)
to 10V input.
Monitors the input level of ana-
log input 3 on a AI-14B option
10 V: 100%
board. A value of 100% is equal
(0 to ± 10 V possible)
to 10V input.
Monitors the calculated value
of the motor secondary current.
10 V:Motor rated current)
The motor rated current corre-
(0 to ±10 V output)
sponds to 100%.
Monitors the calculated value
of the motor excitation current.
10 V:Motor rated current)
The motor rated current corre-
(0 to ±10 V output)
sponds to 100%.
Output Signal Level During
Min.
Unit
-
-
1
hr.
-
0.1%
0.1%
0.1%
0.1%
0.1%
Control Methods
MEMO-
Closed
Open
Closed
BUS
Loop
V/f
Loop
Loop
Register
Vector
Vector
Vector
(PM)
A
A
A
A
4AH
A
A
A
A
4BH
A
A
A
A
4CH
A
A
A
A
4DH
A
A
A
A
4EH
A
A
A
A
4FH
A
A
A
A
50H
A
A
A
A
51H
-
A
A
A
52H