Lift Function Parameters: S - Omron VARISPEED L7 Manual

Hide thumbs Also See for VARISPEED L7:
Table of Contents

Advertisement

Name
Param-
eter
Num-
Display
ber
Fan operation
Sets the initial value of the fan
time setting
operation time.
o2-10
The operation time is accumu-
Fan ON Time Set
lated starting from this set value.
Fault trace
0: No initialisation
1: Initialize (= zero clear) after
initialize
o2-12
setting "1" o2-12 will be
Fault Trace Init
returned to "0"
Number of Trav-
Operation counter initialization.
els counter initial-
0: Number of travels counter is
o2-15
kept
ize
1: Number of travels counter
Initialize Sel
monitor clear
Copy Function: o3
Name
Param-
eter
Num-
Display
ber
Copy func-
0: Normal operation
tion selec-
1: READ (Inverter to Operator)
tion
o3-01
2: COPY (Operator to Inverter)
Copy Func-
3: Verify (compare)
tion Sel
Read per-
mission
0: READ prohibited
selection
o3-02
1: READ permitted
Read
Allowable

Lift Function Parameters: S

:
Brake Sequence
S1
Name
Para-
meter
Num-
Display
ber
Zero speed
Sets the speed level at which the
level at stop
S1-01
DC injection / zero speed operation
starts during stop.
DC Inj I @start
DC injection
Sets the DC injection braking cur-
braking current
S1-02
rent as a percentage of the Inverter
at start
rated current.
DC Inj I @start
DC injection
Sets the DC injection braking cur-
braking current
S1-03
rent as a percentage of the Inverter
at stop
rated current.
DC Inj I @stop
DC injection
Used to set the time to perform DC
braking/ Zero
injection braking at start in units of
speed time at
1 second.
S1-04
start
Used to stop coasting motor and
restart it. When the set value is 0,
DC injection braking at start is not
DC Inj T@start
performed.
Setting
Description
Range
0 to
65535
0 or 1
0 or 1
Setting
Description
Range
0 to 3
0 or 1
Setting
Description
Range
0.0 to
10.0
0 to
100
0 to
100
0.00
to
10.00
Control Methods
Change
Factory
during
Open
Setting
Opera-
V/f
Loop
tion
Vector
0 hr.
No
A
A
0
No
A
A
0
No
A
A
Control Methods
Change
Factory
during
Open
Setting
Opera-
V/f
Loop
tion
Vector
0
No
A
A
0
No
A
A
Control Methods
Change
Factory
during
Open
Setting
Opera-
V/f
Loop
tion
Vector
A
A
i
No
1.2
0.5
Hz
Hz
50%
No
A
A
50%
No
A
A
0.40 s
No
A
A
MEMO-
Closed
Closed
BUS
Page
Loop
Loop
Register
Vector
Vector
(PM)
A
A
50EH
6-66
A
A
510H
6-66
A
A
513H
6-66
MEMO-
Closed
Closed
BUS
Page
Loop
Loop
Register
Vector
Vector
(PM)
A
A
515H
6-66
A
A
516H
6-66
MEMO-
Closed
Closed
BUS
Page
Loop
Loop
Register
Vector
Vector
(PM)
A
A
680H
6-13
0.1 Hz
0.5 Hz
-
-
681H
6-39
-
-
682H
6-39
A
A
683H
6-13
5
47
5-