Output Terminal Functions

The digital multifunction outputs can be set to several functions using the H2-01 to H2-03 parameters (termi-
nal M1 to M6 function selection). These functions are described in the following section.
Related Parameters
Parameter
No.
H2-01
H2-02
H2-03
During Run (Setting: 0) and During Run 2 (Setting: 37)
During Run (Setting: 0)
During Run 2 (Setting: 37)
These outputs can be used to indicate the inverter's operating status.
6
During Run 1 Output
During Run 2 Output
Zero Speed (Setting: 1)
* The Zero Speed Level depends on the control mode. It is 0.1 Hz for Closed Loop Vector, 0.5 Hz for Open Loop Vector and 1.2 Hz for V/f control.
56
6-
Name
Terminal M1-M2 function selection
Terminal M3-M4 function selection
Terminal M5-M6 function selection
OFF
The Run command is OFF and there is not output voltage.
ON
The Run command is ON or a voltage is being output.
OFF
The inverter is not outputting a frequency. (Baseblock, DC injection braking or stopped)
ON
OFF
ON
Run
Baseblock
OFF
ON
DC Inj
Output frequency
OFF
ON
OFF
ON
Fig 6.22 Timing Chart for "During RUN" Output
Output
Frequency
Zero Speed
Output
Fig 6.23 Timing Chart for Zero-speed
OFF
The output frequency is higher than the zero speed level*.
ON
The output frequency is lower than the zero speed level*.
Change
Factory
Setting
0
1
2
The inverter is outputting a frequency.
DC Inj
Zero Speed Level*
OFF
ON
Control Methods
during
Open
Closed
Opera-
V/f
Loop
Loop
tion
Vector
Vector
No
A
A
A
No
A
A
A
No
A
A
A
Closed
Loop
Vector
(PM)
A
A
A