S-Curve Acceleration/Deceleration: C2
Name
Param
eter
Num-
Display
ber
S-curve char-
acteristic time
at accelera-
C2-01
tion start
S-Crv Acc @
Start
S-curve char-
Set the S-curve times at speed changes
acteristic time
to reduce the jerk. The S-curves can be
at accelera-
set separately for every kind of speed
C2-02
tion end
change.
S-Crv Acc @
End
C2-02
S-curve char-
acteristic time
C2-01
at decelera-
C2-03
tion start
= C2-01
T
S-Crv Dec @
accel
Start
= C2-03
T
decel
S-curve char-
acteristic time
When the S-curve characteristic time is
at decelera-
C2-04
set, the accel/decel times will increase
tion end
by only half of the S-curve characteristic
S-Crv Dec @
times at start and end.
End
S-curve Char-
acteristic time
below level-
C2-05
ing speed
Scurve @
leveling
Set-
Description
ting
Range
0.00
to
2.50
0.00
to
2.50
C2-03
C2-05
C2-04
0.00
to
Time
2.50
+ C1-01 + C2-02
2
2
+ C1-02 + C2-04
2
2
0.00
to
2.50
0.00
to
2.50
Control Methods
Change
Fac-
during
Open
Closed
tory
Opera-
V/f
Loop
Setting
tion
Vector
Vector
0.50 s
No
Q
Q
0.50 s
No
Q
Q
0.50 s
No
Q
Q
0.50 s
No
Q
Q
0.50 s
No
Q
Q
MEMO-
Closed
BUS
Page
Loop
Loop
Register
Vector
(PM)
Q
Q
20BH
6-22
Q
Q
20CH
6-22
Q
Q
20DH
6-22
Q
Q
20EH
6-22
Q
Q
232H