Advanced Programming Mode

In the advanced programming mode all Inverter parameters can be monitored and set.
A parameter can be changed from the setting displays using the Increment, Decrement, and Shift/RESET
keys. The parameter is saved and the display returns to the monitor display when the DATA/ENTER key is
pressed.
Refer to
page 5-1, User Parameters
Example Operations
Example key operations in advanced programming mode are shown in the following figure.
Mode Selection Display
-ADV-
** Main Menu **
Programming
MENU
-VERIFY-
** Main Menu **
Modified Consts
MENU
-A.TUNE-
** Main Menu **
Auto-Tuning
MENU
-DRIVE-
** Main Menu **
Operation
MENU
-QUICK-
** Main Menu **
Quick Setting
MENU
Fig 3.7 Operations in Advanced Programming Mode
for details about the parameters.
Monitor Display
A
B
-ADV-
RESET
Initialization
A1-00=0
Select Language
ESC
ESC
-ADV-
RESET
Initialization
A1- 02 =0
Control Method
ESC
-
ADV-
RESET
Accel/Decel
C1- 01 =
1.50sec
Accel Time 1
ESC
-
ADV-
RESET
Accel/Decel
C1- 02 =
1.50sec
Accel Time 1
ESC
A
B
1
2
-
-ADV-
ADV-
Select Language
A1-
00
=
0
*0*
English
"0"
ESC
-
ADV-
-ADV-
Control Method
A1-
02
=
0
A1-02 =
*0*
V/f Control
"0"
ESC
1
2
3
4
-
-
ADV-
ADV-
Accel Time 1
C1- 01 = 001.5sec
C1-
01
=
1.5sec
(0.00 ~ 600.00)
"1.50sec"
ESC
-
-
ADV-
ADV-
Decel Time 1
C1-
02
=
1.5sec
C1- 02 = 001.5sec
(0.00 ~ 600.00)
"1.50sec"
ESC
3
4
Setting Display
Select Language
A1-00 =
0
*0*
English
"0"
Control Method
0
*0*
V/f Control
"0"
Accel Time 1
(0.00 ~ 600.00)
"1.50sec"
Decel Time 1
(0.00 ~ 600.00)
"1.50sec"
3-
3
9