Adjusting the Torque Limit Integral Time (L7-06)
In Open Loop Vector control, during constant speed the limit function works with an integral control part (dur-
ing acceleration and deceleration just a P-control is used). Normally there is no need to change this setting.
Increase the setting if vibrations or short cycle oscillations occur when the motor is running at the set
torque limit
Decrease the setting if long cycle oscillations occur when the motor is running at the set torque limit.
Enabling the Torque Limit Integral Operation during Accel./Decel. (L7-07)
In Open Loop Vector control an integral operation can be applied to the torque limit function (P-control is
standard). This improves the torque limit responsiveness and smoothes the torque limit operation. To enable
the integral operation set parameter L7-07 to 1. The integral time set in parameter L7-07 is used.
Setting Precautions
When the output torque reaches the torque limit, control and compensation of the motor speed is disabled
to prevent the output torque from exceeding the torque limit. The torque limit has the priority.
The torque limit accuracy is ±5% at an output frequency of 10 Hz or above. When output frequency is
lower than 10 Hz, the accuracy is lower.

Motor Overload Protection

The motor can be protected from overload using the built-in electronic thermal overload relay function.
Related Parameters
6
Parameter
No.
E2-01
E4-01
E5-02
L1-01
L1-02
*1. Factory settings depend on Inverter capacity. (The given value is for a 400 V Class Inverter with 3.7 kW.)
Multi-Function Outputs (H2-01 to H2-03)
Set
Value
1F
Motor overload (OL1, including OH3) pre-alarm (ON: 90% or more of the detection level)
Setting the Motor Rated Current (E2-01, E4-01 or E5-02))
Set the rated current value on the motor nameplate in parameters E2-01 (for motor 1), E4-01 (for motor 2) or
E5-02 (PM motor). This set value is the base current for the internal thermal overload calculation.
44
6-
Name
Motor 1 rated current
Motor 2 rated current
PM Motor rated current
Motor protection selection
Motor protection time constant
Change
Factory
during
Setting
Operation
*1
7.00 A
*1
7.00 A
*1
7.31 A
1
1.0 min
Function
Control Methods
Open
Closed
V/f
Loop
Loop
Vector
Vector
No
Q
Q
Q
No
Q
Q
Q
No
Q
Q
Q
No
Q
Q
Q
No
A
A
A
Control Methods
Open
Closed
V/f
Loop
Loop
Vector
Vector
Yes
Yes
Closed
Loop
Vector
(PM)
-
-
-
A
-
Closed
Loop
Vector
(PM)
Yes
Yes

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents