Inverter Operation Ready (Setting: 6)
If a multifunction output is set to this function, the output is switched ON when the initialisation of the
inverter at startup has been finished without any faults.
During DC Bus Undervoltage (Setting: 7)
If a multifunction output is set to this function, the output is switched ON as long as a DC bus under voltage is
detected.
During Baseblock (Setting: 8)
If a multifunction output is set to this function, the output is switched ON as long as the inverter output is base
blocked.
Frequency Reference Source Selection (Setting: 9)
If a multifunction output is set to this function, the output is ON when the digital operator is selected as fre-
quency reference source. If any other frequency reference is selected the output is switched OFF.
Run Command Selection Status (Setting: A)
If a multifunction output is set to this function, the output is switched ON when the digital operator is selected
as RUN command source. If any other RUN command source is selected the output is switched OFF.
Fault Output (Setting: E)
If a multifunction output is set to this function, the output is switched ON when any fault different from
CPF00 and CPF01 occurs. The output is also not switched at minor faults. (Refer to
pp. for a fault list.)
Minor Fault Output (Setting: 10)
If a multifunction output is set to this function, the output is switched ON when a minor fault occurs (refer to
page 7-9, Alarm Detection
Fault Reset Command Active (Setting: 11)
If a multifunction output is set to this function, the output is switched ON as long as a fault reset command is
input at one of the digital inputs.
Timer Function Output (Setting: 12)
Refer to
page 6-52, Using the Timer
During Reverse Run (Setting: 1A)
If a multifunction output is set to this function, the output is switched ON whenever a RUN command in
reverse direction is active (also during DC injection and base block) It is OFF when a forward RUN is input.
During Base Block 2 (Setting: 1B)
If a multifunction output set to this function is switched OFF as long as a Baseblock command is input.
Motor 2 selected (Setting: 1C)
If a multifunction output is set to this function, the output is switched OFF when motor 1 is selected and
switched ON if motor 2 is selected.
pp. for an alarm list).
Function.
page 7-2, Fault Detection